BOEHRINGER MANNHEIM CORPORATION -- ALKALINE PHOSPHATASE, 556602 -- 6550-00N092974
===================== Product Identification ===================== Product ID:ALKALINE PHOSPHATASE, 556602 MSDS Date:10/23/1997 FSC:6550 NIIN:00N092974 Status Code:A === Responsible Party === Company Name:BOEHRINGER MANNHEIM CORPORATION Address:9115 HAGUE RD Box:50414 City:INDIANAPOLIS State:IN ZIP:46250-0100 Country:US Info Phone Num:317-845-2000 Emergency Phone Num:317-845-2000 Resp. Party Other MSDS Num.:556602 Preparer's Name:MICHAEL A. FAZIO CAGE:32239 === Contractor Identification === Company Name:BOEHRINGER MANNHEIM CORPORATION Address:9115 HAGUE RD Box:50414 City:INDIANAPOLIS State:IN ZIP:46250-0100 Country:US Phone:317-845-2000 CAGE:32239 ============= Composition/Information on Ingredients ============= Ingred Name:NON-HAZARDOUS INGREDIENTS ===================== Hazards Identification ===================== Routes of Entry: Inhalation:NO Skin:YES Ingestion:NO Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO Health Hazards Acute and Chronic:THE TOXICOLOGICAL PROPERTIES OF THIS PRODUCT HAVE NOT BEEN DETERMINED. Explanation of Carcinogenicity:THIS PRODUCT CONTAINS NO CARCINOGENS (NTP, IARC, OR OSHA). Effects of Overexposure:SEE HEALTH HAZARDS. Medical Cond Aggravated by Exposure:NOT APPLICABLE. ======================= First Aid Measures ======================= First Aid:EYES: FLUSH CONTAMINATED EYE(S) WITH LARGE VOLUMES OF WATER FOR AT LEAST 15 MINUTES. GET MEDICAL ATTENTION IF EYE(S) REMAIN IRRITATED. SKIN: FLUSH CONTAMINATED AREAS WITH LARGE VOLUMES OF WATER FOR AT LEAST 15 MINUTES AS CONTAMINATED CLOTHING IS REMOVED. GET MEDICAL ATTENTION IF AREA REMAINS IRRITATED. DO NOT WEAR CONTAMINATED CLOTHING UNTIL AFTER IT HAS BEEN PROPERLY CLEANED. INGESTION: KEEP VICT IM WARM & CALM. GET IMMEDIATE MEDICAL ATTENTION. INHALATION: REMOVE VICTIM TO FRESH AIR. GIVE OXYGEN IF BREATHING BECOMES DIFFICULT. SHOULD BREATHING STOP - GIVE ARTIFICIAL RESPIRATION. ===================== Fire Fighting Measures ===================== Flash Point:>200.C, 392.F Extinguishing Media:NO SPECIFIC INFORMATION IS KNOWN OF THE FLASH POINTS OR EXPLOSION LIMITS. USE MEDIA SPECIFIC FOR SITE CONDITIONS. Fire Fighting Procedures:USE NIOSH APPROVED SCBA AND FULL PROTECTIVE EQUIPMENT . IF POSSIBLE HAVE THIS PRODUCT REMOVED FROM THE FIRE SCENE. Unusual Fire/Explosion Hazard:NOT APPLICABLE. NFPA HAZARD IDENTIFICATION RATING SYSTEM: HEALTH - 1; FIRE - 0; REACTIVITY - 0. ================== Accidental Release Measures ================== Spill Release Procedures:VENTILATE THE AREA. INITIATE CLEANING UP THE SPILL USING THE EQUIPMENT AND MATERIALS AS NOTED IN THE EXPOSURE CONTROL INFORMATION SECTION. IF PRODUCT IS DRY, MOP UP. IF PRODUCT IS IN SOLUTION, USE ABS ORBENT MATERIAL TO CLEAN UP SPILLED SOLUTION. ONCE ABSORB SPENT, PLACE ALL CONTAMINATED DISPOSABLES INTO A SUITABLE CONTAINER, SEAL, LABEL AND HOLD FOR DISPOSAL. ====================== Handling and Storage ====================== Handling and Storage Precautions:SEE PACKAGE INSERT FOR STORAGE INFORMATION. GOOD LABORATORY TECHNIQUE SHOULD BE USED WHEN HANDLING THIS PRODUCT. DO NOT MOUTH PIPETTE! OBSERVE APPROPRIATE CHEMICAL HYGIENE AND AVOID CONTACT WITH SKIN OR EYES. Other Precautions:DO NOT EAT, DRINK OR SMOKE WHILE WORKING WITH REAGENTS. ============= Exposure Controls/Personal Protection ============= Respiratory Protection:NIOSH APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN . NONE REQUIRED IF VENTILATION IS ADEQUATE. Ventilation:PROVIDE ADEQUATE GENERAL EXHAUST VENTILATION. Protective Gloves:RUBBER OR CHEMICAL RESISTANT GLOVES. Eye Protection:ANSI APPROVED CHEMICAL WORKERS GOGGLES . Other Protective Equipment:ANSI APPROVED EYE WASH & DELUGE SHOWER . A LAB COAT SHOULD BE WORN. Work Hygienic Practices:UPON COMPLETION OF WORK ACTIVITIES INVOLVING THIS PRODUCT, WASH ANY EXPOSED BODY AREAS THOROUGHLY WITH SOAP AND WATER. Supplemental Safety and Health MFR'S FAX NUMBER: +1 (317) 576-4409. ================== Physical/Chemical Properties ================== Vapor Pres:NOT APPLICABLE (MMHG) Vapor Density:N/A(AIR=1) Spec Gravity:NOT APPLICABLE (WATER=1) Evaporation Rate & Reference:NOT APPLICABLE (N/I=1) Solubility in Water:PROD SHOULD BE FAIRLY SOL Appearance and Odor:PRE-PACKED COLUMNS. ================= Stability and Reactivity Data ================= Stability Indicator/Materials to Avoid:YES NOT APPLICABLE. Stability Condition to Avoid:STABLE UNDER NORMAL HANDLING AND STORAGE CONDITIONS. AVOID EXCESS HEAT, FLAME AND PRESSURE. Hazardous Decomposition Products:NOT APPLICABLE. ==================== Disposal Considerations ==================== Waste Disposal Methods:DISPOSE OF I/A/W STATE, LOCAL AND FEDERAL REGULATIONS. ===================== Regulatory Information ===================== State Regulatory Information:WARNING: THIS PRODUCT CONTAINS CHLOROFORM WHICH IS KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER AND/OR REPRODUCTIVE TOXICITY. ======================= Other Information ======================= Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever, expressly or implied, warrants this information to be accurate and disclaims all liability for its use. Any person utilizing this document should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation.