CAMBRIDGE DIAGNOSTIC PRODUCTS INC -- ERADA-STAIN TUBE(CREAM), 206 -- 7930-01-225-9237
=====================  Product Identification  =====================

Product ID:ERADA-STAIN TUBE(CREAM), 206
MSDS Date:07/01/1996
FSC:7930
NIIN:01-225-9237
=== Responsible Party ===
Company Name:CAMBRIDGE DIAGNOSTIC PRODUCTS INC
Address:6880 NW 17TH AVE
City:FORT LAUDERDALE
State:FL
ZIP:33309
Country:US
Info Phone Num:954-971-4040
Emergency Phone Num:954-971-4040;800-424-9300(CHEMTREC)
Preparer's Name:TOM MAUTHNER
CAGE:0P2F6
=== Contractor Identification ===
Company Name:CAMBRIDGE CHEMICAL PRODUCTS INC
Address:6880 NW 17TH AVE
Box:City:FT LAUDERDALE
State:FL
ZIP:33309
Country:US
CAGE:1AD19
Company Name:CAMBRIDGE DIAGNOSTIC PRODUCTS INC
Address:6880 NW 17TH AVE
Box:City:FT LAUDERDALE
State:FL
ZIP:33309-5000
Country:US
Phone:305-971-4040
CAGE:0P2F6

=============  Composition/Information on Ingredients  =============

Ingred Name:ETHYL ALCOHOL (ETHANOL)
CAS:64-17-5
RTECS #:KQ6300000
Fraction by Wt: 10%
OSHA PEL:1000 PPM
ACGIH TLV:1000 PPM

Ingred Name:ETHANOL, 2,2',2"-NITRILOTRI-; (TRIETHANOLAMINE)
CAS:102-71-6
RTECS #:KL9275000
Fraction by Wt: 2%
OSHA PEL:N/K 
ACGIH TLV:5 MG/M3

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:NO	Skin:NO  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:ACUTE:NO SIGNIFICANT SIGNS OR SYMPTOMS
    INDICATIVE OF ANY ADVERSE HEALTH HAZARD ARE EXPECTED TO OCCUR FROM
    INHALATION OR SKIN ABSORPTION. EYE:CONTACT MAY CAUSE IRRITATION.
    INGESTION:MAY CAUSE DIZZINESS , VOMITING, DROWSINESS, DEPRESSION
    AND DIARRHEA.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE KNOWN AT THIS TIME.

=======================  First Aid Measures  =======================

First Aid:INHAL:REMOVE TO FRESH AIR. SUPPORT BREATHING (GIVE O*2/ARTF
    RESP) . SKIN:FLUSH W/COPIOUS AMOUNTS OF WATER. CALL MD .
    EYES:IRRIGATE WITH WATER OR EYEWASH FOR AT LEAST 15 MINUTES.
    INGEST:GIV E 2 GLASSES OF WATER, INDUCE VOMITING AND SEEK MEDICAL
    ATTENTION.

=====================  Fire Fighting Measures  =====================

Extinguishing Media:NONE. MEDIA SUITABLE FOR SURROUNDING FIRE .
Fire Fighting Procedures:NONE. USE NIOSH APPROVED SCBA & FULL
    PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE.

==================  Accidental Release Measures  ==================

Spill Release Procedures:SHOVEL INTO WASTE DISPOSAL CONTAINER AND CLEAN
    WITH WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:DO NOT TAKE INTERNALLY. KEEP AWAY FROM
    ANY SOURCE OF HEAT OR OPEN FLAME.
Other Precautions:NONE.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NONE REQUIRED. NIOSH APPROVED RESPIRATOR
    APPROPRIATE FOR EXPOSURE OF CONCERN .
Ventilation:NOT APPLICABLE.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPRVD EYE WASH & DELUGE SHOWER .
Work Hygienic Practices:DO NOT TAKE INTERNALLY.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.

==================  Physical/Chemical Properties  ==================

HCC:N1
Boiling Pt:B.P. Text:202F,94C
Solubility in Water:NOT COMPLETE
Appearance and Odor:PASTE MATERIAL - SLIGHT PERFUME ODOR.

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
NONE.
Stability Condition to Avoid:AVOID HIGH TEMPERATURES - MAY CAUSE THE
    FORMATION OF CARBON MONOXIDE.
Hazardous Decomposition Products:NONE.

====================  Disposal Considerations  ====================

Waste Disposal Methods:REMOVE TO DRY FILL AREA, FLUSH WITH WATER. USE
    NORMAL WASTE DISPOSAL. DISPOSAL MUST BE I/A/W FEDERAL, STATE &
    LOCAL REGULATIONS .

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.