BELZONA AMERICA INC -- 1024/0866, BELZONA 1111 BASE -- 8030-00-187-7747
=====================  Product Identification  =====================

Product ID:1024/0866, BELZONA 1111 BASE
MSDS Date:02/17/1992
FSC:8030
NIIN:00-187-7747
Kit Part:Y
=== Responsible Party ===
Company Name:BELZONA AMERICA INC
Address:2000 NW 88 COURT
City:MIAMI
State:FL
ZIP:33172
Country:US
Info Phone Num:305-594-4994
Emergency Phone Num:305-594-4994 OR 305-274-6512
Preparer's Name:J. PARTINGTON
CAGE:0PX05
=== Contractor Identification ===
Company Name:BELZONA  INC.
Address:2000 N. W. 88 COURT
Box:City:MIAMI
State:FL
ZIP:33172
Country:US
Phone:305-594-4994
CAGE:0PX05

=============  Composition/Information on Ingredients  =============

Ingred Name:DGBA EPOXY RESINS
CAS:25068-38-6
RTECS #:SL6475000
Fraction by Wt: 10-30%
Other REC Limits:NONE RECOMMENDED

Ingred Name:EPOXIDIZED PHENOL-FORMALDEHYDE NOVOLAC
CAS:28064-14-4
Fraction by Wt: 10-30%
Other REC Limits:NONE RECOMMENDED

Ingred Name:MODIFIED SILICA
CAS:92797-60-9
Fraction by Wt: 1-5%
Other REC Limits:NONE RECOMMENDED

=====================  Hazards Identification  =====================

Routes of Entry: Inhalation:NO	Skin:YES  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:ACUTE: SKIN AND EYE IRRITATION.
    CHRONIC: IRRITATION, SENSITIZATION AND DERMATITIS.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:SKIN SENSITIZER AND SKIN IRRITATION.
Medical Cond Aggravated by Exposure:SKIN & EYE CONDITIONS.

=======================  First Aid Measures  =======================

First Aid:INHALE-REMOVE SOURCE OF CONTAMINATION &/OR MOVE VICTIM TO
    FRESH AIR. IF RECOVERY IS DELAYED, OBTAIN MEDICAL ATTENTION.
    EYE-FLUSH W/WATER FOR AT LEAST 15 MINS. IMMEDIATE FIRST AID IS
    NEEDED TO PREVENT  EYE DAMAGE. SEEK PHYSICIAN. SKIN-IMMEDIATELY
    REMOVE EXCESS WITH A CLEAN CLOTH & WASH W/SOAP & WATER. SEE
    PHYSICIAN. INGEST-DO NOT INDUCE VOMITING. RINSE MOUTH WITH WATER &
    DRINK 1 CUP WATER. SEE DOC.

=====================  Fire Fighting Measures  =====================

Flash Point Method:SCC
Flash Point:>392F,>200C
Lower Limits:NIA
Upper Limits:NIA
Extinguishing Media:WATER FOG (NOT A DIRECT STREAM OF WATER), FOAM,
    CARBON DIOXIDE & DRY CHEMICAL.
Fire Fighting Procedures:WEAR PROTECTIVE CLOTHING & USE SELF-CONTAINED
    BREATHING APPARATUS. FULL BUNKER GEAR SHOULD BE WORN IN EXTREME
    CASES. USE SAND TO CONTAIN BURNING MATERIAL.
Unusual Fire/Explosion Hazard:DECOMPOSITION AND COMBUSTION PRODUCTS MAY
    BE HAZARDOUS.

==================  Accidental Release Measures  ==================

Spill Release Procedures:ABSORB W/AN INERT MATERIAL (E.G. EARTH/SAND) .
    SWEEP UP, PLACE INTO SUITABLE LABELLED CONTAINERS, SEAL & DISPOSE
    OF PROPERLY. FLUSH AREA W/DETERGENT & WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:CONTAINERS SHOULD BE STORED UNDER
    COOL, DRY CONDITIONS. OVERHEATING MAY CAUSE CONTRS TO RUPTURE.
    EMPTY CONTRS WILL RETAIN RESIDUE & MAY BE DANGEROUS.
Other Precautions:CHECK ALL CONTAINERS FOR LEAKS AT REGULAR INTERVALS &
    BEFORE USE. AVOID BREATHING VAPORS & CONTACT W/SKIN & EYES.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:IN CONFINED AREAS OR WHERE GOOD NATURAL/MECH
    VENT IS NOT AVAIL, LEADING TO RISK OF EXCEEDING TLV'S INDICATED, OR
    WHERE MACHINING/ABRADING OF CURED MATL LEADS TO PRODUCTION OF
    RESPIRABLE &/OR NUISANCE  DUST, AN APPROVED RESPIRATOR WORN.
Ventilation:WHERE ADEQUATE NATURAL VENTILATION IS NOT AVAILABLE PROVIDE
    SUITABLE LOCAL EXHAUST VENTILATION.
Protective Gloves:IMPERMEABLE GLOVES (NEOPRENE OR PVC).
Eye Protection:SAFETY GLASSES OR GOGGLES.
Other Protective Equipment:WHERE THERE IS RISK OF CONTAM OF FOOTWEAR,
    SAFETY BOOTS SHOULD BE WORN & CLEANED THORO BEFORE REUSE.
Work Hygienic Practices:WHEN USING, DO NOT EAT, DRINK OR SMOKE. REMOVE
    CONTAMD CLTHG & LAUNDER BEFORE REUSE. WASH HANDS W/SOAP & WATER.
Supplemental Safety and Health
NONE.

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:DECOMPOSES
Vapor Pres:NIA
Vapor Density:NIA
Spec Gravity:2.80
Evaporation Rate & Reference:N.AP
Solubility in Water:NEGLIGIBLE
Appearance and Odor:DARK GRAY PASTE WITH EPOXY ODOR.
Percent Volatiles by Volume:N.AP

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS, ACIDS, BASES AND AMINES.
Stability Condition to Avoid:NOT APPLICABLE.
Hazardous Decomposition Products:GASEOUS COMBINATION OF CARBON,
    HYDROGEN, & OXYGEN MAY OCCUR AT ELEVATED TEMPERATURE.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE &
    FEDERAL REGULATIONS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.